Autoclave unwrapped cycle time: do all healthcare instruments need to be bagged for sterilization?

17-11-2023

In Celitron’s next article, we will explore the concept of the unwrapped autoclave cycle and its significance in healthcare settings.

Autoclaves play a pivotal role in healthcare facilities, serving as the frontline defense against the spread of infections. Their primary function is to sterilize medical instruments and equipment, ensuring patient safety by eliminating harmful microorganisms. One common practice in autoclave sterilization is to wrap or bag instruments before placing them in the autoclave. However, a vital question arises: Is it necessary to bag all healthcare instruments for sterilization in an autoclave?


The unwrapped autoclave cycle explained

The unwrapped autoclave cycle represents a sterilization process designed for instruments that do not require the additional protection of wrapping or bagging. Steam sterilizers can have many different cycle settings during which they use high-pressure and high-temperature steam to treat the medical instruments that were loaded inside their chamber.

In contrast to wrapped cycles, which involve packaging instruments in materials like sterilization pouches or wraps, the unwrapped cycle exposes instruments directly to high-temperature steam within the autoclave chamber.

When medical instruments are not properly sterilized, the risk of infection and cross-contamination between patients increases significantly. In surgical procedures, where the use of sterile instruments is critical, the unwrapped cycle time can be a matter of life and death.


The bagging dilemma: Necessity or choice? Advantages of unwrapped autoclave cycles

Now, let's address the question: Is bagging necessary for the sterilization of all healthcare instruments? While bagging is a common practice, it may not be mandatory for all instruments.


1. Compatibility

Unwrapped autoclave cycles offer versatility in sterilizing a wide range of healthcare instruments. Instruments made of materials that can withstand high temperatures and moisture, such as stainless steel, are prime candidates for unwrapped cycles. Additionally, unwrapped cycles are well-suited for instruments with complex shapes or larger sizes that may not be easily accommodated in sterilization pouches or wraps. The autoclave's steam penetration can effectively sterilize these items without the need for a bag.

IMPORTANT NOTE FROM CELITRON: ALWAYS check the manufacturer’s instructions, as models can vary in their versatility. NEVER put any material inside the chamber that is not compatible with the model you own!


2. Time efficiency

Unwrapped autoclave cycles excel in time efficiency. This method offers a quicker and more straightforward sterilization process. They are typically shorter in duration compared to wrapped cycles, making them ideal for healthcare settings where rapid instrument turnaround is essential, such as emergency surgical procedures. Faster sterilization times mean healthcare professionals can access sterilized instruments promptly, enhancing the efficiency of medical procedures and reducing patient wait times.


3. Resource conservation and eco-friendly practices

The absence of wrapping materials in unwrapped cycles has significant implications for resource conservation. Wrapped autoclave cycles typically require sterilization pouches or wraps, consuming materials and resources. By opting for unwrapped cycles when appropriate, healthcare facilities can substantially reduce their consumption of these materials, leading to cost savings and contributing to environmental sustainability. This aligns with broader healthcare sustainability goals, which aim to minimize waste and reduce the environmental footprint of medical practices. Hospitals and clinics are increasingly focusing on environmentally responsible practices, and reducing bag usage in autoclaves is a step in the right direction.


Factors influencing unwrapped cycle time

The unwrapped cycle time is directly related to patient safety. Several factors affect the duration of the unwrapped cycle in autoclaves.

Understanding these factors is vital for optimizing the sterilization process in healthcare facilities. If the cycle is too short, the items inside won’t be 100% sterile. If it’s too long, you increase patient wait times.


1. Type of instrument

Different healthcare instruments have varying requirements for sterilization. While some instruments can be effectively sterilized without the need for bags, others may require additional precautions. Surgical instruments like scissors, forceps, and clamps are examples of items that can often be sterilized unwrapped due to their design and material.


2. Size of instrument

The size of an instrument can also impact the unwrapped cycle time. Larger instruments may require more time to ensure that steam penetrates every surface, reaching all potential hiding spots for microorganisms. Proper sterilization is essential regardless of an instrument's size, so healthcare facilities must account for these variations.


3. Autoclave settings

The settings of the autoclave itself play a significant role in determining the unwrapped cycle time. The temperature, pressure, and duration of the cycle can be adjusted based on the specific needs of the instruments being sterilized. Fine-tuning these settings ensures that sterilization is both effective and efficient.


Considerations for using unwrapped autoclave cycles

While the advantages of unwrapped autoclave cycles are evident, it is crucial to consider several factors before implementing them in a healthcare facility.


1. Instrument compatibility:

The first and foremost consideration is whether the instruments to be sterilized are compatible with the unwrapped cycle. Instruments that are heat and moisture-tolerant are ideal candidates for this type of sterilization. Stainless steel instruments, for example, are commonly sterilized using unwrapped cycles due to their durability and resistance to high temperatures and moisture.

Delicate or sensitive instruments may still require bagging to prevent damage during the sterilization process. Healthcare facilities must strike a balance between efficiency and instrument protection to ensure the longevity of their equipment.


2. Wrapped autoclave cycles

Wrapped autoclave cycles involve packaging healthcare instruments in materials like sterilization pouches or wraps before sterilization. These cycles are necessary for instruments that require added protection during sterilization. Wrapped cycles are commonly used for instruments that are not heat or moisture-tolerant, as they provide a barrier to protect the instruments from steam and heat.

IMPORTANT NOTE FROM CELITRON: Class B autoclaves can handle both unwrapped and wrapped cycles. Lower-class autoclaves that use gravity cycles instead of vacuum pumps may only be used to treat flat solid products with simple designs (meaning no porous or hollow items, or textile-based materials).


3. Manufacturer guidelines

We cannot emphasize this enough. Healthcare facilities must ALWAYS consult the manufacturer's guidelines for healthcare instruments to ensure that using an unwrapped cycle is within their recommended sterilization protocols. Manufacturers often provide specific instructions for the proper sterilization of their products, including information on cycle types, temperature settings, and cycle times. Adhering to these guidelines is essential to ensure the effectiveness of the sterilization process and to maintain instrument integrity.


4. Infection control practices

The primary objective of sterilization is to prevent the transmission of infections. Therefore, infection control practices should always be at the forefront of decision-making regarding autoclave cycles. Healthcare facilities must follow established infection control guidelines and protocols to safeguard the safety of patients and healthcare workers. It is essential to strike a balance between time efficiency and safety to ensure that the sterilization process effectively eliminates pathogens without compromising patient care.


Achieving optimal autoclave unwrapped cycle times with Celitron’s class B steam sterilizers

Celitron is a reliable autoclave manufacturer in Europe with a trusted global distribution network. Our class B steam sterilizers represent the most advanced class on the market. Our models are equipped with powerful vacuum pumps to ensure thorough sterilization and optimal wrapped and unwrapped cycle times, regardless of size and capacity.

This is why we are confident we can provide an optimal solution for all kinds of medical facilities.


1. Advantages of high-quality vacuum autoclaves

Investing in high-quality autoclaves with advanced features can significantly impact the duration of this process. Celitron’s autoclaves come equipped with enhanced steam penetration capabilities that can reduce the duration of unwrapped cycle times to about 20 minutes. The user-friendly controls of our steam sterilizers also allow for precise customization. Our preset settings also include wrapped cycles, but you can also customize up to 20 different cycles according to your needs.


2. Routine maintenance facilitated with self and remote diagnosis options

Regular maintenance of autoclaves is crucial to ensure their efficiency. Healthcare facilities should establish maintenance schedules and promptly address any issues that may affect the unwrapped cycle's performance. This includes checking for worn gaskets, ensuring proper water levels, and calibrating temperature and pressure sensors. In the case of Celitron’s autoclaves, they are equipped with remote diagnosis options and test functions to facilitate maintenance checks, but you can also count on our after-sales support team.


3. Easier staff training thanks to user-friendly interface and clear guidelines

Properly trained staff members are essential for the effective use of autoclaves. Training programs should cover the operation of autoclaves, instrument preparation, and adherence to manufacturer guidelines. Well-trained personnel can contribute significantly to reducing cycle times while maintaining sterilization efficacy. Celitron’s autoclaves operate fully automatically – the whole cycle process can be launched with the push of a button, and all relevant information is displayed via an LCD screen.


4. Monitoring and validation via PC connection and software

Continuous monitoring and validation of autoclave sterilization processes are vital. Regular testing ensures that the equipment consistently meets the required sterilization standards. Facilities should implement comprehensive quality control measures to guarantee the safety of patients and healthcare providers. With Celitron’s autoclaves, you can document all cycle data via a PC connection and our monitoring and control software.


Make your medical facility’s day-to-day operations easier with a quality autoclave that can handle both unwrapped and wrapped cycle times optimally!

CONTACT CELITRON right away, and our team of experts will get back to you as soon as possible with a free price quote!

Celitron use cookies and other similar technologies on this website to improve your browsing experience and functionality of our site. By clicking "I accept cookies", you consent to the storing on your device of all the technologies described in our Cookie Policy.